Raytek Compact GP Infrared Pyrometer | Fluke by Muser
Raytek Compact GP Infrared Pyrometer | Fluke by Muser Spot Pyrometers Pyrometers Fluke Kuala Lumpur (KL), Malaysia, Selangor, Sunway Velocity Supplier, Suppliers, Supply, Supplies | Muser Apac Sdn Bhd
Fluke Raytek® Compact GP Infrared Pyrometer
General purpose, compact, two-piece temperature monitoring system
 
 
Versatile. Compact. Value-priced.
  • Improve process control with instant noncontact temperature readings
  • Easily configure sensor parameters through display monitor
  • Choose from the standard or close focus optics
  • AVAILABLE IN APAC (ASIA-PACIFIC) AND AMERICAS ONLY
Raytek GP infrared pyrometers provide process temperature control in hard-to-reach, small or distant targets in temp range from -18 to 538°C (0 to 1000°F).
 
 
Description
 
The GP Series, consisting of GPR and GPS models, is a versatile, two-piece temperature monitoring system that combines a compact, value-priced monitor with an infrared sensing head. The heart of the system is the 1/8 DIN GP monitor which provides advanced infrared processing capabilities including peak and valley hold, averaging, and a user-adjustable offset.

The Compact GPR model is available with standard or close focus optics and provides target temperature readings with 1% accuracy.

In addition, the GPS model features laser sighting and standard optical Distance to Spot (D:S) ratio of 50:1, allowing for easier sensor alignment in hard-to-reach, small or distant targets. The GPS integrated coaxial Class 2 laser is connected to the remote activation switch box via the included 4 m (13 ft) cable. An additional 8 m (26 ft) of cable is also included to connect the switch box to the GP monitor.
 
Key Features:
  • Read temperature ranges from -18 to 538°C (0 to 1000°F)
  • Available with standard or close focus optics
  • Withstand ambient temperatures without cooling: monitor up to 50°C (120ºF) and the sensing head up to 65°C (150°F) .
  • Accessories for air purging and water/air cooling
  • Compact 1/8 DIN digital monitor with large 4-digit display
  • Monitor and sensor functions configured on front panel
  • Response time: 300 mSec
  • Adjustable emissivity and T-ambient parameters
  • Adjustable dual setpoints, deadband alarm outputs and optional mechanical relays
  • Field interchangeable sensing heads
 
 
Technical Specifications
 

Model Number GPR Standard Focus GPR Close Focus GPS Standard Focus GPS Close Focus
Temperature Range -18° to 538°C
(0 to 1000° ºF)
Spectral Response 8 to 14 μm
System Accuracy ±1% of reading or ±1°C (2°F), whichever is greater, @23°C ±5°C (73°F ±9°F)
Repeatability ±0.5% of measured value or ±1°C (2°F), whichever is greater
Optical Resolution (D:S) 35:1 30 : 1 50 : 1 45 : 1
Response Time 300 mSec
Emissivity Adjustable; 0.10 to 1.09 for all models
Signal Processing Peak and valley hold (up to 998 sec, 999=infinite hold with external reset).
Variable averaging filter (up to 60 seconds). T-ambient: fixed background ambient temperature compensation
Ambient Temperature 0°C to 65°C (32°F to 150°F)
with optional water cooling: 0°C to 177°C (32°F to 350°F)
with optional air cooling: 0°C to 120°C (32°F to 250°F)
GPS laser shuts off automatically at 50°C (120°F)
Storage Temperature -30°C to 65°C (-22°F to 150°F)
Environmental Rating IP 65 (IEC 529); NEMA-4
 
 
Monitor Specifications
 

Environmenal Rating GP Front Panel IP54 (IEC 529); NEMA-12
Ambient Temperature Range 0 to 50°C (32 to 120°F
Storage Temperature -30 to 65°C (-22 to 150°F)
GP Monitor Dimensions 1/8 DIN x 120 mm (1.75 x 3.63 x 4.75 in)
GP Monitor Weight 320 g (0.7 lbs)
 
 
Applications
 
Compact GP pyrometers can be used across numerous industries and are ideal for a variety of OEM and end-user manufacturing applications including the list below and many others.
  • Paper Processing and Converting including: printing, coating, laminating, drying/curing
  • Plastic Processing
  • Asphalt
  • Pharmaceuticals
  • Textiles
 
 
Accessories
 
Each GP sensor system is comprised of the GPR or GPS sensing head, the 1/8 DIN monitor, and an additional 8 m (26 ft) connector cable.
 
Accessories for GPR/GPS Sensing Heads
  • Accessory air purge collar to keep lens clean (XXXTXXACAP)
  • Accessory conduit adapter, adapts sensor threads to .5 in. NPT (XXXTXXACCA)
  • Accessory pipe adapter, adapts sensor threads to 1.5 in. NPT (XXXTXXACPA)
  • Accessory right angle mirror, provides perpendicular view of target in tight installations (XXXTXXACRA)
  • Optional air/water cooled housing for installation in environments up to 177ºC (350ºF)
  • Optional NIST traceable calibration certificate
 
Accessories for GP Monitor
  • Accessory mounting bracket for sub-panel installation (XXXGPACFB)
  • Accessory solid state relays, 10 Amp AC (X XXGPSSRAC)
  • Optional 3A mechanical relays (RAYGPCM must be specified at time of order)
 
 
Downloads


Product Literature:

Manuals:
 

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf
Switch To Desktop Version