PCE-TDS 200 M Ultrasonic Flow Meter | PCE Instruments by Muser
PCE-TDS 200 M Ultrasonic Flow Meter | PCE Instruments by Muser Ultrasonic Flow PCE Instruments Kuala Lumpur (KL), Malaysia, Selangor, Sunway Velocity Supplier, Suppliers, Supply, Supplies | Muser Apac Sdn Bhd
PCE Instruments PCE-TDS 200 M Ultrasonic Flow Meter
 
 
Features
  • Measuring range ±32 m/s
  • USB-C interface for data transfer 
  • Optional software for analysing the measured values
  • Reproducibility ±0.5 % of measured value 
  • Heat quantity measurement
  • Data memory for 10 million measuring points
  • Individually adjustable alarm limits
  • Optionally with ISO or DAkkS calibration certificate
 
 
Description
 
Ultrasonic flow meter with 32 GB data memory / measuring range ±32 m/s / reproducibility ±0.5 % of measured value / different measuring probes / alarm limit values / 2.8 '' LC display / for all media / optionally with DAkkS or ISO calibration certificate
 
The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob. 
 
During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval from 1 second to 12 hours can be set for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.
 
With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software. 
 
In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per heat quantity unit simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.
 
The LC colour display of the ultrasonic flow meter has a size of 2.8'' and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate. 
 
 
PCE-TDS 200 M SENSOR
 
Medium sensor pair for pipe diameters DN 50 ... 700 / 57 ... 720 mm. Suitable for flow measurement on medium-sized pipes. The sensors of the ultrasonic flow meter can be attached to ferrous pipes with the built-in magnets. Alternatively, the sensors can be mounted to the pipe with detachable cable ties. The temperature resistance is between -30 ... 160 °C.
 
 
Technical Specifications
 

Flow measurement  
Measuring range ±32 m/s
Accuracy 0,001 m/s
Genauigkeit DN ≥50 mm: ±1.5 % rdg. for velocities > 0.3 m/s
  DN <50 mm: ±3.5 % rdg. for velocities > 0.3 m/s
Reproducibility ±0.5 % of measured value
 
PCE-TDS 200 M SENSOR Sensor pair
Pipe diameter DN 50 ... 700 / 57 ... 720 mm
 Temperature resistance -30 ... 160 °C
 
Measuring method Z, V, N, W
Medium
 
 
 
 
 
 
 
 
 
- water
- sea water
- oil
- crude oil
- methanol
- ethanol
- diesel
- petrol
- petroleum
- user defined
(manual input of the sound velocity from the medium)
 
All liquids with an impurity <5 %
Pipe material
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
- copper CU
- steel FE
- stainless steel VA
- aluminium AL
- brass ME
- cast iron CI
- iron FE
- nickel NI
- titanium TI
- zink ZI
- acrylic AC
- polyethylene PE
- polypropylene PP
- polyvinyl chloride PVC
- nylon NY
- user defined
(manual input of the transversal sound velocity
of the pipe material)
 
Inner pipe lining
 
 
 
 
 
 
 
 
 
 
 
- no lining
- user defined
- epoxy resin
- rubber
- mortar
- polystyrene PS
- polyethylene PE
- polytetrafluoroethylene PTFE
- polyurethane PU
- polypropylene PP
- user defined
(manual input of the longitudinal sound velocity
of the inner lining of the pipe)
 
Measurement parameters flow velocity, volume flow and volume
Units (dimensions) mm, in
Units (flow velocity) m/s, ft/s
Units (volume flow) m³, l, gal, igl, mgl, cf, bal, ib, ob
Time specification seconds, minutes, hours, days
Units (volume) m³, l, gal, igl, mgl, cf, bal, ib, ob
 
Further specifications  
2.8'' LCD 2,8“ LCD
Menu metric / imperial
Menu languages German, English, French, Spanish, Italian, Dutch, Portuguese, Danish, Turkish, Polish, Russian, Chinese, Japanese
Operating and storage conditions
 
 Temperature: -20 ... +65 °C
Humidity: 10 ... 95 % r. h., non-condensing
Data logger 32 GB memory capacity / 10 million measuring points
Interface USB (for online measurement, readout of the internal memory and for recharging the battery)
Protection class IP52
Power supply Internal
 
Internal: LiPo battery (3.7 V, 2500 mAh)
External: USB 5 VDC, 500 mA
Operating time approx. 10 h
Dimensions 165 x 85 x 32 mm
Weight 255 g
 
 
Delivery Scope
  • 1 x Ultrasonic flow meter PCE-TDS 200 M
  • 1 x flow sensor PCE-TDS 200 M SENSOR (pair)
  • 2 x 5 m connection cable 
  • 2 x detachable cable ties
  • 1 x power supply unit
  • 1 x USB-C cable
  • 1 x ultrasonic contact gel 
  • 1 x PCE measuring tape
  • 1 x plastic case
  • 1 x instruction manual
 
 
Downloads
 
 

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf